S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › ACSX6 ACSX6 / 020C

Right pressure sensor (pin B8) is short circuit to ground.

â–¶ How to fix

- Check wiring to right pressure sensor (T754). - Check connectors on both ACSX (E752) and right pressure sensor. - Perform voltage reading between sensor signal (B8) and ground.

What you'll see

Nothing noticeable to the driver.

System reaction

Amber ACS warning lamp

Diagnostic depth

Detection

Voltage on analogue input 1 is below 250 mV for more than 1 second.

Possible cause

- Defect cable connecting ACSX (E752) and right pressure sensor (T754). - Defect connectors on either ACSX or right pressure sensor - Defect pressure sensor (internal circuit broken)

{ } Raw XML
diag