DTC › ACSX6 ACSX6 / 0242

Electrical installation fault

â–¶ How to fix

• If the connectors are mixed between ACS and ACSX, an equal DTC should be active in the ACS node (E751). If it is active, switch the connectors to the other ECU. • If they are connected correctly, make sure that the jump wires connected to the ID pins are not damaged on the ACSX node. Pin A5 and A6 should be connected to the ID_GND pins A8 and A2.

What you'll see

Strange reading on pressure sensor right (T754) Electrical error DTC on pressure sensor left (T753)

System reaction

Red ACS stop lamp Speed & Torque Limitation

Diagnostic depth

Detection

Incorrect coding of the four ID pins in the connector.

Possible cause

• ECU has been connected to the wrong cable harness, i.e. mixed up with the ACS node. • Jump wires has been damaged on the ID pins so the connector is incorrectly identified as belonging to the ACS node's cable harness.