Right pressure sensor (pin B8) is short circuit to battery (+24 V) or +5 V.
â–¶ How to fix
- Check wiring to right pressure sensor (T754). - Check connectors on both ACSX (E752) and right pressure sensor. - Perform voltage reading between sensor signal (B8) and ground.
What you'll see
Nothing noticeable to the driver.
System reaction
Amber ACS warning lamp
Diagnostic depth
Detection
Voltage on analogue input 1 is above 4750 mV for more than 1 second.
Possible cause
- Defect cable connecting ACSX (E752) and right pressure sensor (T754). - Defect connectors on either ACSX or right pressure sensor - Defect pressure sensor (internal circuit broken)