S Scania Multi 📌 unpin — ▢ ×
Pinned chassis: 3250642 T113H4X2L 942652 Unpin
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › APS1 APS1 / 02A7 2 variants

Pressure regulation

â–¶ How to fix

Check the compressor solenoid valve using the diagnostics program. Check the compressed air pipes between the APS and compressor. Check the compressor. Renew defective components. Erase the fault code.

What you'll see

No driver-visible symptom recorded.

System reaction

No system-reaction text recorded.

Diagnostic depth

Detection

The air pressure increases when the control unit has switched off the compressor.

Possible cause

Electrical or mechanical fault in the control unit, compressor or solenoid valve. The fault may also be caused by leaks in the pneumatic signal pipe between the APS and compressor.

⊕ 1 other variants — show diff { } Raw XML
diag