S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › BMU5 BMU5 / 0326 4 variants

Coolant level sensor MGS sensor fault

â–¶ How to fix

• Check that the sensor T182 is connected. • Check that connector E81-B is connected. • Check that the coolant level is within an acceptable range in the expansion tank for the battery thermal management system. If the level is too low check for leakages. If glycol or traces of glycol is found in the HRU/HPU the leakage has to be located and repaired. • Check that the cable harness by measuring that E81-B13 is connected to T182-B, E81-B10 is connected to T182-A and E81-B15 is connected to T182-C. If there is no connection, change the cable. • Apply 24V on the component with + on T182-B and – on T182-A and measure the outgoing voltage between T182-A and T182-C. If the voltage is >2V, change the sensor. • Change the BMU(E81)

What you'll see

No driver-visible symptom recorded.

System reaction

• Coolant pump MGS stops, the hybrid power is reduced to prevent over temperature in the MGU or DCC. • Amber warning lamp "Hybrid System Fault" is shown in ICL

Diagnostic depth

Detection

Level sensor feedback

Possible cause

• Sensor not connected • Damaged connectors or cables • Sensor malfunction

⊕ 3 other variants — show diff { } Raw XML