S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › CCC1 CCC1 / A02A

12V supply to LIN node is short circuit to ground.

â–¶ How to fix

Check the cable harness.

What you'll see

No driver-visible symptom recorded.

System reaction

Components connected to the LIN bus will not function.

Diagnostic depth

Detection

The supply voltage is measured by the climate control system (E138). The test is performed when the supply is active.

Possible cause

The supply cable harness is short circuit to ground.