S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › CCC1 CCC1 / A058

Secondary Wake Up output is short circuit to ground.

â–¶ How to fix

Check the cable harness.

What you'll see

No driver-visible symptom recorded.

System reaction

It will not be possible for the climate control system to activate other systems connected to the wake up bus when the ignition is off.

Diagnostic depth

Detection

The wake up signal voltage level is measured by the climate control system (E138). The test is performed when the wake up is active.

Possible cause

The wake up signal cable harness is short circuit to ground.