S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › COO9 COO9 / 0223

Retarder lever sensor short circuit to ground.

â–¶ How to fix

• Check the connectors and wiring • Check the control lever. • Measure the sensor voltage between signal and ground.

What you'll see

No driver-visible symptom recorded.

System reaction

Manual retarder brake will not function as long as the fault is present.

Diagnostic depth

Detection

Impermissible signal from the control lever for auxiliary brake control. The sensor voltage level too low. The auxiliary brake lever sensor is short circuit to ground.

Possible cause

• Short circuit to ground on retarder lever signal (pin A5) • Faulty control lever unit • Faulty connectors.

{ } Raw XML