S Scania Multi 📌 unpin — ▢ ×
Pinned chassis: 1158127 R113ML4X2L 36050Z 942650 Unpin
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › COO9 COO9 / 031A

Communication error on the LIN bus

â–¶ How to fix

• Measure the resistance (with the battery disconnected) between LIN-bus (pin B8) and supply. It should be high ohmic (Mega ohm). • Measure the resistance (with the battery disconnected) between LIN-bus (pin B8) and ground. It should be high ohmic (Mega ohm). • Disconnect one LIN node unit at the time from the LIN-bus and check if the fault disappears. • Check if there is any short circuit in the connector for LIN bus (pin B8).

What you'll see

No driver-visible symptom recorded.

System reaction

• Switches connected to the LIN IO-node and Remote Control Units for air suspension functions will not work.

Diagnostic depth

Detection

Communication error. There is a short circuit on the LIN-bus to ground or supply voltage

Possible cause

• Defect wiring of LIN-bus: - short circuit between LIN-bus and supply voltage. - short circuit between LIN-bus and ground. • Defect LIN unit(s) on the LIN-bus.

{ } Raw XML
diag