Overload on right cornering lamp

â–¶ How to fix

Check the number of loads connected. Also check for short circuit in the cable harness (pin A17).

What you'll see

No driver-visible symptom recorded.

System reaction

The output is permanently turned off until the function is deactivated.

Diagnostic depth

Detection

Overload on cornering light right output

Possible cause

Short circuit or too high load on the cornering light right output. The problem could also depend on short circuit in cable harness.