S Scania Multi 📌 unpin — ▢ ×
Pinned chassis: 1158117 P93ML4X2R 25034Z 942649 Unpin
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › DCU3 DCU3 / 0600

DCU temperature too high

â–¶ How to fix

- Turn off the DCU and let it cool down to room temperature before attempting to use the system again. The safest way is to remove the fuse to the VBAT power supply to the DCU. - Make sure that the DCU has sufficient cooling, that air can circulate freely through the heat sink. - Make sure that no strong heat source is close to the DCU. - If the above provisions are OK and the DTC is set repeatedly, contact Scania Global Technical Support for advice.

What you'll see

The system does not neccessarily show any symptoms but may function partially in an unpredictable way. If the temperature is far over the limit it may not function at all. The DCU housing is hot.

System reaction

No system-reaction text recorded.

Diagnostic depth

Detection

Internal temperature sensors in the DCU has detected a temperature over 100°C for more than 30 seconds.

Possible cause

-Insufficient cooling of the DCU -Hardware failure

{ } Raw XML
diag