S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › EACS1 EACS1 / 00010A

Outer fan fault

â–¶ How to fix

Clean the outer fan Test fan with DID 0xFE51 and check fan status with DID 0xFE0D Replace the outer fan

What you'll see

None

System reaction

Possibly DTC 0x000109 - "e-motor over temperature condition" set

Diagnostic depth

Detection

The DTC is set to active if: • The e-motor outer fan speed is below ½ of the nominal fan speed AND • The fan is activated AND • At least 10 seconds have passed since the start of the fan activation The DTC is set to inactive if: • The e-motor outer fan speed is above ½ of the nominal fan speed The fan is automatically activated by the ECU when any of the following internal sensor conditions are fulfilled: • PCB temperature sensor indicate a temperature ≥ 50 °C • Power stage temperature sensor indicate a temperature ≥ 70 °C • e-motor temperature sensor indicate a temperature ≥ 90 °C • Capacitor temperature sensor indicate a temperature ≥ 55 °C The fan is automatically inactivated by the ECU when all of the following internal sensor conditions are fulfilled: • PCB temperature sensor indicate a temperature < 40 °C • Power stage temperature sensor indicate a temperature < 60 °C • e-motor temperature sensor indicate a temperature < 80 °C • Capacitor temperature sensor indicate a temperature < 45 °C The DTC is not set in the following cases: • VCA is below 22 V

Possible cause

Debris in fan Fan broken

{ } Raw XML
diag