Oil level switch circuit shorted

▶ How to fix

Check sensor cable harness including connectors. Replace if necessary. Perform a power reset by turning the vehicle ignition off/on. Check oil level switch: 1. Make sure the amount of oil in the compressor is according to the specification. Fill up oil if necessary. 2. Reset the ECU and wait for at least 9 seconds 3. Readout the oil level switch status using DID 0xFE00. Check that the status is “Oil level Ok” 4. Drain out the oil 5. Reset the ECU and wait for at least 9 seconds 6. Readout the oil level switch status using DID 0xFE00. Check that the status is “Oil level low” 7. If any of the tests fail, replace the oil level switch. 8. Fill up the specified amount of oil Details regarding how to, please check the service manual §Trouble shooting.

What you'll see

None

System reaction

Amber warning lamp lit

Diagnostic depth

Detection

The DTC is set to active if: • The oil level switch supply is continuously detected as shorted to ground during the startup measuring period* OR • The oil level switch output is continuously detected as shorted to ground during the startup measuring period* The DTC is set to inactive if: • The oil level switch supply is not detected as short circuit during a startup measuring period* AND • The oil level switch output is not detected as shorted to ground during a startup measuring period* *The startup measuring period for the oil level takes place between t=6 and t=9 seconds after ECU start-up. The DTC is not set in the following cases: • VCA is below 22 V • VCA is above 30 V

Possible cause

Oil level switch supply wire shorted to ground, or oil level switch output signal shorted to ground or supply.

{ } Raw XML
diag