S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › EAS2 EAS2 / 0BBB00

Write access to data flash failed.

â–¶ How to fix

Step.1: If Updated/Newer SW is available: Flash SW. Step-2: Perform proper Clamp_15-Reset with stable PowerSupply as follows: - Vehicle in Stand-Still (0kmph, Parking-Brake-Enganged) - Clampe_15_ON + wait 5 seconds - Clampe_15_OFF + wait 5 seconds - Clampe_15_ON + wait 5 seconds - If Error is still active (DTC-Status-TestFailed) remain with Step-3 Step-3: Replace the power pack if the SPN is still active.

What you'll see

Not applicable

System reaction

Set the Yellow Lamp to "On". Set the signal EASState to ERROR. Set the EPS motor torque to 0 Nm. Electronic steering system is inactive. The software endstops are deactivated. DTC, KFC_ERROR_MODE_ACTIVE is set ACTIVE in the same Klemme-15 cycle. ActualSteeringMode signal stay in ASM mode. Steering gear operational mode is in Disable Steering gear degradation reason is in Internal Fault Note:ASM functionality deactivate

Diagnostic depth

Detection

Internal Data Flash error.

Possible cause

1. Wrong software version flashed to powerpack. 2. Defective powerpack

{ } Raw XML
diag