0xD9060D Pressure Control Modulator-Out Of Calibration
â–¶ How to fix
Action: Check the type of the PCM's (1 channel / 2 channel) and download a new dataset. If the error is still active, replace the PCM.
What you'll see
Symptom:
System reaction
SystemReaction: All user functions are off. Red Warning Lamp.
Diagnostic depth
Detection
Detection: The error is set if a PCM sents reconfiguration request more than once in the same power-on cycle.
Possible cause
Cause: Not valid PCM is connected (1ch<->2ch), NVM memory of any PCM's is demaged, PCM is demaged