S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › EML1 EML1 / 0034 4 variants

Turbocharger/Supercharger Bypass Valve Control Circuit Low

â–¶ How to fix

Check dump control valve solenoid V189 and/or V190 for short circuit to ground.

What you'll see

No driver-visible symptom recorded.

System reaction

Dump valves can dump as soon as pressure in inlet manifold is below 0, 7 Bar. Could lead to bad drivability at part load.

Diagnostic depth

Detection

Fault is detected only when engine is running.

Possible cause

Check dump control valve solenoid for short circuit to ground.

⊕ 3 other variants — show diff { } Raw XML