S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › EML1 EML1 / 0035 4 variants

Turbocharger/Supercharger Bypass Valve Control Circuit High

â–¶ How to fix

Check dump control valve solenoid V189 and/or V190 for short circuit to battery.

What you'll see

No driver-visible symptom recorded.

System reaction

Not possible to dump pressure when closing throttle. Can lead to bad air mass estimation at tip outs which will lead to jerks. Compressor could go into surge with a increased level of noise when trying to dump pressure.

Diagnostic depth

Detection

Fault is detected only when engine is running.

Possible cause

Dump control valve solenoid, V189 and/or V190: short circuit to battery.

⊕ 3 other variants — show diff { } Raw XML