Pinned chassis: 1158127 R113ML4X2L 36050Z 942650 Unpin
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC β€Ί EML1 EML1 / 0249 4 variants

Turbocharger/Supercharger Wastegate Solenoid "B" Low

β–Ά How to fix

Check the connectors and wiring to the wastegate actuator. Check the wastegate actuator Measure resistance of wastegate actuator, the resistance shall be around 30 Ohm at 20ΒΊ C.

What you'll see

No driver-visible symptom recorded.

System reaction

The wastegate actuator will not work which might impact turbo performance and the wastegate over speed protection.

Diagnostic depth

Detection

Short circuit low to battery voltage (U30) or short circuit high to ground (U31)in the Wastegate actuator circuit.

Possible cause

Short circuit low to battery voltage or short circuit high to ground in the Wastegate actuator circuit.