S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › ICL3 ICL3 / 000906

Illumination of switches 1 (PWM1): Shortcut to ground

â–¶ How to fix

1. Remove some of the consumers from the harness. 2. Check the harness.

What you'll see

No driver-visible symptom recorded.

System reaction

PWM1 is turned off. It could be turned on after switching wakeup1 off/on, when fault is fixed.

Diagnostic depth

Detection

The feedback for the load for PWM1 is indicating short circuit to GND Only stored when ignition is ON.

Possible cause

1. The harness is shorted to ground 2. Too many consumers (i.e.LEDs) are connected to the harness.

{ } Raw XML
diag