Extra sensor 1
â–¶ How to fix
1. Check the sensor, connectors and wiring. 2. Disconnect connector C241. 3. Check that the resistance when the sensor is open is infinite. 4. Check that the resistance when the sensor is closed is 900-1100. 5. Check that the voltage on pin C241-1 is more than 9 V. If the voltage is too low: check that the wiring to the alarm control unit is not shorted to earth. 6. Check that pin C241-2 is connected to earth via the alarm control unit.
What you'll see
No driver-visible symptom recorded.
System reaction
No system-reaction text recorded.
Diagnostic depth
Detection
The voltage on the alarm control unit input has been below 3 V.
Possible cause
The fault can be caused by the following: - Short circuit to earth in the sensor - Short circuit in the wiring between the alarm control unit and the sensor