#Not implemented. Electrical error on CAN bus 2

â–¶ How to fix

• Check wiring for CAN bus 2: - Measure the resistance (with the battery disconnected) between CAN-high and CAN-low. It should be close to 60 ohm (one 120 ohm termination resistor in each end of the CAN-bus). - Measure the resistance (with the battery disconnected) between CAN-high on MBS and CAN-high on any other unit (e.g. MBS) on CAN bus 2. It should be close to zero ohm. - Measure the resistance (with the battery disconnected) between CAN-low on MBS(Master) and CAN-low on any other unit on CAN bus 2. It should be close to zero ohm. Trouble shoot CAN bus cable harness and connectors

What you'll see

Functionality connected to MBS expansion nodes A, B, C and D may not work as intended.

System reaction

Functions dependent on information from CAN bus 2 are degraded, meaning components connected to MBS expansion node A, B, C and D.

Diagnostic depth

Detection

The CAN-controller of CAN bus 2 has entered state bus-off, which indicates a communication error. There is a short circuit on CAN bus 2.

Possible cause

• Defect wiring of CAN bus 2: - short circuit between CAN-high and CAN low. - short circuit between CAN-high and supply voltage. - short circuit between CAN-high and ground. - short circuit between CAN-low and supply voltage. - short circuit between CAN-low and ground. • Defect ECU unit(s) on the CAN bus 2.