S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › MBS3 MBS3 / 021E

#Not implemented. Electrical error on CAN bus 3

â–¶ How to fix

• Check connector for CAN bus 3 on MBS • Check wiring for CAN bus 3: - Measure the resistance (with the battery disconnected) between CAN-high (pin CN5_6) and CAN-low. It should be close to 60 ohm (one 120 ohm termination resistor in each end of the CAN-bus). - Measure the resistance (with the battery disconnected) between CAN-high on MBS and CAN-high on any other unit (e.g. MBS_x) on the CAN bus 3. It should be close to zero ohm. - Measure the resistance (with the battery disconnected) between CAN-low on MBS and CAN-low on any other unit on CAN bus 3. It should be close to zero ohm. • Check wiring and connector, the ignition signal The result of the reciving and transmitting messages is evaluated

What you'll see

Components connected to MBS expansion nodes J, K, L and M may not work as intended.

System reaction

Functions dependent on information from CAN bus 3 are degraded, meaning components connected to MBS expansion nodes J, K, L and M.

Diagnostic depth

Detection

The CAN-controller of CAN bus 3 has entered state bus-off, which indicates a communication error. There is a short circuit on CAN bus 3.

Possible cause

• Defect wiring of CAN bus 3: - short circuit between CAN-high and CAN low. - short circuit between CAN-high and supply voltage. - short circuit between CAN-high and ground. - short circuit between CAN-low and supply voltage. - short circuit between CAN-low and ground. • Defect ECU unit(s) on CAN bus 3.

{ } Raw XML
diag