S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › MBS3 MBS3 / 021F

#Not implemented. Absence of CAN bus 3 communication

â–¶ How to fix

• Trouble shoot CAN bus 3 cable harness and connectors. • Check connector for CAN bus 3 on MBS • Check wiring for CAN bus 3: - Measure the resistance (with the battery disconnected) between CAN-high and CAN-low. It should be close to 60 ohm (one 120 ohm termination resistor in each end of the CAN-bus). - Measure the resistance (with the battery disconnected) between CAN-high on MBSM and CAN-high on any other unit on CAN bus 3. It should be close to zero ohm. - Measure the resistance (with the battery disconnected) between CAN-low on MBS and CAN-low on any other unit on CAN-bus 3. It should be close to zero ohm.

What you'll see

MBS expansion node J, K, L and M are connected to CAN bus 3, meaning that components connected to those nodes may not work as intended.

System reaction

Functions dependent on information from CAN bus 3 are degraded/missing in MBS (Master)

Diagnostic depth

Detection

The fault is validated as present if the ECU does not detect communication on CAN bus 3 within the timeout period

Possible cause

• Defect wiring for CAN bus 3. • Defect ECU unit(s) on CAN bus 3.