CAN timeout of MBS_A
Check the fuse, connectors, and cable harness and power supply failure.
What you'll see
Components connected to MBS expansion node A may not work as intended.
System reaction
An amber warning will be shown in the ICL. Expansion node's LED indicator: - No LED is powered or flashing. (Dead expansion node) - Orange LED blinking every second (Application is running) - Yellow LED is not active (No CAN traffic) - Orange LED triple flashing (Application is not executing) Functions dependent on information from MBS_A might be degraded in MBS(Master)
Diagnostic depth
Communication MBS_A node has timed out. Communication interrupted or missing
The fault is most likely in the MBS_A unit or the pink CAN bus. • Power supply to MBS_A has failed. • MBS_A unit disconnected from the pink CAN bus • Faulty or dead MBS_A unit - During production the fault is most likely uninstalled expansion unit or incorrect installed expansion or dead expansion