CAN timeout of MBS_B
Check the fuse, connectors, and cable harness and power supply failure.
What you'll see
Components connected to MBS expansion node B may not work as intended.
System reaction
An amber warning will be shown in the ICL. Expansion node's LED indicator: - No LED is powered or flashing. (Dead expansion node) - Orange LED blinking every second (Application is running) - Yellow LED is not active (No CAN traffic) - Orange LED triple flashing (Application is not executing) Functions dependent on information from MBS_B might be degraded.
Diagnostic depth
Communication MBS_B node has timed out. Communication interrupted or missing.
The fault is most likely in the MBS_B unit or the pink CAN bus. • Power supply to MBS_B has failed. • MBS_B unit disconnected from the pink CAN bus • Faulty or dead MBS_B unit - During production the fault is most likely uninstalled expansion unit or incorrect installed expansion or dead expansion