S Scania Multi 📌 unpin — ▢ ×
Pinned chassis: 1158127 R113ML4X2L 36050Z 942650 Unpin
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › MBS3 MBS3 / 0324

Primary passenger area refrigerant system high pressure

â–¶ How to fix

Check components in refrigerant refrigerant system

What you'll see

Cooling in passenger areais not working when expected to

System reaction

Compressor running is not allowed and condenser fans are forced to run to lower pressure Amber warning lamp will be shown in ICL

Diagnostic depth

Detection

High pressure switch or sensor has reported high pressure.

Possible cause

Possible causes for high pressure are: fault in condenser fans (not running), broken hp switch / sensor reporting wrong value, or compressor running when not supposed to do so, or too high ambient temperature for the system ~45-50cdeg, or too high fill of refrigerant in the system

{ } Raw XML
diag