S Scania Multi 📌 unpin — ▢ ×
Pinned chassis: 1158122 P113HL6X4R 36031Z 942652 Unpin
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › MCC3 MCC3 / A019

Actuator panel/floor (M57) LIN error.

â–¶ How to fix

Check the cable harness for the panel/floor motor, if no fault is found, replace the panel/floor motor. This unit is connected to the climate control system via a LIN-bus. If one of the units on the LIN-bus is faulty it can affect the other units further down the same communication line. The LIN-units are split into three lines from C8061, one to the sun sensor, one to the humidity sensor via C24, and one to multiple units via C8046. From C8046 the units are arranged: air intake/recirc control motor, air dist/defrost. motor, mix air/temp flap motor, panel/floor flap dist. motor, 2nd recirc/AQS motor and AQS-sensor.

What you'll see

No driver-visible symptom recorded.

System reaction

The panel/floor flap will not function.

Diagnostic depth

Detection

The climate control system (17) has detected a LIN communication error with the actuator. The test is performed continuously when the supply to the LIN nodes is active.

Possible cause

There may be an internal error in the actuator or an error in the cable harness.

{ } Raw XML
diag