Pinned chassis: 1158126 T113EL4X2L 31042Z 942649 Unpin
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › MCC3 MCC3 / A037

Over temp reported by the air dist/defrost motor (M59).

â–¶ How to fix

Check that the air dist/defrost flap can move freely, if no fault is found, replace the air dist/defrost motor. This unit is connected to the climate control system via a LIN-bus. If one of the units on the LIN-bus is faulty it can affect the other units further down the same communication line. The LIN-units are split into three lines from C8061, one to the sun sensor, one to the humidity sensor via C24, and one to multiple units via C8046. From C8046 the units are arranged: air intake/recirc control motor, air dist/defrost. motor, mix air/temp flap motor, panel/floor flap dist. motor, 2nd recirc/AQS motor and AQS-sensor.

What you'll see

No driver-visible symptom recorded.

System reaction

The mix air dist/defrost flap may not function.

Diagnostic depth

Detection

The climate control system (E17) has detected the actuator reports an error.

Possible cause

The actuator is overheated.