Low DC-Bus Voltage

â–¶ How to fix

Bad connection between MGU and propulsion battery, check connections.

What you'll see

Linear reduction of propulsion torque from MGS starts at 550V and ends at 500V

System reaction

Max allowed accelerating AC current is reduced linearly. Yellow OBD

Diagnostic depth

Detection

Evaluation Condition When ignore low DC bus bit <69J01301C12x06.htm> is not active. Set Condition Event is set if filtered voltage is below predefined level. Clear Condition Event is cleared when filtered voltage is above predefined level.

Possible cause

No power source connected on DC bus External power source with low DC bus voltage Attempt to enable without closing main contactor Fuse is blown Acceleration torque exceeds battery's limits (e.g. cold battery) Internal sensor failure

{ } Raw XML