S Scania Multi πŸ“Œ unpin β€” β–’ Γ—
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC β€Ί MGU2 MGU2 / 0B00

MGU Temperature Sensor Not Connected

β–Ά How to fix

Erase trouble code and restart ECU. If fault still present, reflash ECU (both β€œhalves”) and restart ECU.

What you'll see

Reduced torque from MGS

System reaction

Reduce AC current to 50%. Yellow OBD

Diagnostic depth

Detection

Evaluation Condition Always. Set Condition Disconnected error counter is increased with one every 20 ms when the unfiltered sensor value measures above 130 Β°C, otherwise it is decreased with one. Set condition is when error counter reaches 10. Clear Condition Clear condition is when error counter reaches 0.

Possible cause

Internal hardware failure. (No Connection in the internal temp sensor)

{ } Raw XML
diag