S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › OCS1 OCS1 / 00D100

Lambda sensor upstream catalyst

â–¶ How to fix

- Check primary oxygen sensor LSU lines before catalyst - Check primary oxygen sensor LSU plug connection before catalyst and EGC4 - Renew primary oxygen sensor LSU before catalyst

What you'll see

No driver-visible symptom recorded.

System reaction

- Lambda regulation is locked - Vehicle has higher emissions - Engine runs disturbed - Vehicle might sutter on dynamic drive

Diagnostic depth

Detection

- Sensor temperature ist to low - tkerlsu_w < TKERLSUDMN

Possible cause

- Heater of Primary oxygen sensor defect - Heater is weak

{ } Raw XML
diag