Check that the diaphragm pump is not blocked or defective. If it is, renew the diaphragm pump.Switch off the power with the starter key, wait for at least 90 seconds and switch on the power with the starter key again. If the fault code is still active, the SCR control unit should be renewed; this means that the main unit must be renewed.Proceed as follows to verify that the fault has been rectified: Switch off the power with the starter key, wait for at least 90 seconds and switch on the power with the starter key again. If the fault has been rectified, the fault code becomes inactive. Clear the fault code.Switch the power off and on with the starter key three times in succession at 10 second intervals to extinguish the warning lamp.
What you'll see
No driver-visible symptom recorded.
System reaction
No system-reaction text recorded.
Diagnostic depth
Incorrect or unreliable data.
Internal fault in the control unit.