DTC › S6 S6 / 102F 4 variants

SCR - Reductant pressure

â–¶ How to fix

Dosage test with air and reductant under User function in SDP3 can be used as a function check for the entire system after possible faults have been rectified.Check that there is reductant in the tank.Check that the tank ventilation is working.Check if the reductant lines are leaking or are blocked. Pressurise the tank to 0.5 bar for one minute. Use Test equipment for SCR system 99628. Look for reductant leaks in the double wall in the reductant pick-up unit hose.Check that the hose clamps on the tank pick-up unit are in the right place. Tighten or add new hose clamp. It is also possible to replace the tank pick-up unit with a new one with a thicker connection.Check whether the prefilter or the main filter is blocked.Make sure there is fuel in the tank. If there is fuel in the tank, the tank should be cleaned and the diaphragm pump, ventilating valve, and filter in the main unit should be renewed.Check whether there is fuel in the pump. If there is fuel in the pump, then the pump, gaskets, filter and ventilating valve must be renewed.Check the signal from the pressure sensor for the reductant.Check that heating of the reductant tank is working.Check that the reductant doser can close completely by running System checks 1–3.Fault code 4143 (EMS) may also be due to the valve plate in the pump expanding as a result of fuel. A deformed valve plate means that the pump fails to build up pressure. Check whether there is fuel in the filter.

What you'll see

No driver-visible symptom recorded.

System reaction

No system-reaction text recorded.

Diagnostic depth

Detection

The pressure has not increased enough after the reductant pump has been started at full capacity.

Possible cause

Possible faults:Air is drawn in at the double-walled hose above the main unit.The reductant hoses are leaking or are blocked.The main unit has been irreparably damaged as a result of diesel entering the reductant tank.The heating system in the tank does not work in cold weather.Tank ventilation does not work.The prefilter in the tank or the main filter in the main unit is blocked.The reductant doser is not fully closed.Internal fault in the main unit.Fault on the pressure sensor.The ventilating valve is stuck open.The prefilter in the main unit is blocked.

⊕ 3 other variants — show diff { } Raw XML
diag