SCR - Main unit
Check that the diaphragm pump is not defective. If it is, renew the diaphragm pump.Pressurise the reductant tank to check that there is no reductant leakage between the reductant tank and the main unit.If there are no leaks: Switch off the power with the starter key, wait for at least 90 seconds and switch on the power with the starter key again. If the fault code is still active, the SCR control unit should be renewed; this means that the main unit must be renewed.Proceed as follows to verify that the fault has been rectified:Switch off the power with the starter key, wait for at least 90 seconds and switch on the power with the starter key again.If the fault has been rectified, the fault code becomes inactive. Clear the fault code.Switch the power off and on with the starter key three times in succession at 10 second intervals to extinguish the warning lamp.
What you'll see
No driver-visible symptom recorded.
System reaction
No system-reaction text recorded.
Diagnostic depth
The speed of the diaphragm pump in the main unit has been above the permitted level.
The fault may be due to:Air in the reductant suction pipe.Internal fault in the main unit.