Pump motor speed in the EEC system

â–¶ How to fix

Clear the fault codes. Turn the ignition off, wait for at least 90 seconds and turn the ignition on. Repeat this a few times. If the fault code is regenerated, check urea lines and connections between the pump and tank for leakage. Note that it may take up to 90 seconds before the system shuts down after switching the starter key off.If fault code 1020 for internal leakage is generated, trouble shoots through that.If the fault still remains, renew the EEC system.For engines with NOx-control software, confirmation of repair requires:- Turn the ignition off, wait at least 90 s- Turn the ignition on If the fault is remedied, the DTC should now be passive.

What you'll see

No driver-visible symptom recorded.

System reaction

The EEC system will not inject any urea, which leads to higher emissions.

Diagnostic depth

Detection

The pump motor speed is above 4500 rpm, which is the over speed condition.(Refer BOSCH SW-specification Y281S01334-VC0 for more details. Error path: ep04_s_def_ouw.3, pump_s_def_ouc.1.)

Possible cause

The pump motor over speed might be caused by: - Air in the urea suction line, - Internal leakage after the pump, - Defect pump urea level sensor. urea level sensor.