S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › TPM1 TPM1 / 27FB 2 variants

BUS OFF

â–¶ How to fix

Check external wiring – remove failure Exchange IVTM immediately..

What you'll see

No driver-visible symptom recorded.

System reaction

Full tire pressure monitoring but no signalization via CAN

Diagnostic depth

Detection

Direct by CAN controller when voltage is in normal range *) *) Normal voltage operating range according to SCANIA document TB1700 (date 2000-01-28; Issue 1). A threshold of 0,6 V is implemented when the supply voltage increase from Low Voltage or decreases from High Voltage. With this the threshold values are: OverVoltageSetThr= 30 V -> a supply voltage above this level is detected as over voltage and will suppress the CAN BUS OFF detection OverVoltageResetThr= 29,4 V -> the supply voltage must fall below this level after detection of over voltage to enable the CAN BUS OFF detection again LowVoltageSetThr= 22 V -> a supply voltage below this level is detected as low voltage and will suppress the CAN BUS OFF detection LowVoltageResetThr= 22,6 V -> the supply voltage must rise above this level after detection of low voltage to enable the CAN BUS OFF detection again

Possible cause

The CAN bus is shortened.

⊕ 1 other variants — show diff { } Raw XML