Sensor registration status signal not available.

â–¶ How to fix

1. Perform EOL parameterization or Sparepart programing in Instrument Panel. 2. Check fault memory of Instrument Panel. 3. Replace TPM ECU.

What you'll see

It is not possible to perform sensor registration via Instrument Panel. Malfunction warning is displayed in the instrument panel.

System reaction

Sensor registration function is disable.

Diagnostic depth

Detection

The DTC will set during the following conditions: 15 and 30 are On; Power supply voltage level within 18 Volts and 32 Volts; Sensor registration status signal is not available on CAN bus.

Possible cause

Sensor registration status signal is not available: 1. Instrument Panel is not configured to support TPM system; 2. Instrument Panel is damaged; 3. TPM ECU is damaged.