Altimeter / Pitch
â–¶ How to fix
Change transmission control unit and send it to Voith customer service for diagnosis.
What you'll see
No driver-visible symptom recorded.
System reaction
No topographically conditioned switching program possible. No system limitation.
Diagnostic depth
Detection
Malfunction of the air pressure sensor / sensor only delivers a constant value.
Possible cause
Internal control unit defect of the E300.1 hardware.