S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › WTA2 WTA2 / 11F0E7

0x11F0E7, No Start / Max. Fuel Priming Time Exceeded

â–¶ How to fix

- check fuel supply - check air inlet and exhaust pipes - for further information see workshop manual - clear error memory

What you'll see

No driver-visible symptom recorded.

System reaction

- this DTC is stored in the error memory. - start procedure is aborted - failure afterrun is initiated Heater Actions: * This DTC is an error * Temporary Interlock is activated * counter "FSZ / failed start coutner" is incremented

Diagnostic depth

Detection

Enable Condition: This error is only detected while starting phase. (LS.Internal.HeaterStateSimplified = HeaterBurnerStarting) Mature Threshold: Formation of flame not detected within 240 seconds of fuel feeding. (legislation) This DTC is reported by the heater core software. De-mature Criteria: Stable combustion reached after restart of heater: Heating request is switched off (HeaterModeRequest = DeactivateHeater) and on (HeaterModeRequest = NormalMode) and state HEATER RUNNING is reached

Possible cause

- no stable flame even after repetition of start procedure (bad fuel supply, blocked combustion air system, worn burner assembly, worn glow plug)

{ } Raw XML