S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › ZF4 ZF4 / FF0038

EF2_ELECTRIC; Output shaft speed; Electrical error

â–¶ How to fix

Switch off ignition; Disconnect electronics from transmission; Connect terminal tester between TCU and transmission; Switch on ignition; Measure voltage between pin 10 (EF2) and pin 15 (AU2) Nominal value: 5V; Switch off ignition; Disconnect electronics; Measure resistance between pin 15 (AU2) and ground / housing Nominal value: >10 Mohm; Measure resistance between pin 10 (EF2) and ground / housing Nominal value: >10 Mohm; If you find deviations from nominal value, check wiring, component, and TCU;

What you'll see

No driver-visible symptom recorded.

System reaction

Deactivate Neutral Standby;Deactivate Automatic Idle Shift;Switch off engine brake (If available);Deactivate shifting pressure adaption and use last adaption values;Special fast procedure to change into Neutral gear;Increase main pressure up to a certain value;Reduced retarder torque;Reduced engine torque;Switch to duty cycle signal Limp Home from Shift Console;EFP restrictions;Switch off Comfort start;short time slip of lock up clutch locks;Permit reverse gear only when braking and reverse from first gear via Neutral on Shift Console (In a certain time and n_Tu=0);Change only into a certain high gear if Neutral -> D is pressed on the Shift Console;

Diagnostic depth

Detection

Readback voltage outside valid value; Normal mode

Possible cause

Increased fuel consumption Reduced driving performance Reduced retarder braking performance;

{ } Raw XML
diag