DTC ›
PDS1
| Code | Heading | Variants |
|---|---|---|
| 100001 | Overvoltage at main power supply | — |
| 100002 | Undervoltage at main power supply | — |
| 100006 | Short circuit to ground on auxiliary wake up | — |
| 100007 | Short circuit to supply or implausible value on door sensor | — |
| 100008 | Short circuit to supply or implausible vaule on latch sensor | — |
| 100009 | Short circuit on power supply output to windowlifter sensor or windowlfiter actuator is not connected | — |
| 10000A | Short circuit on main mirror actuator output | — |
| 10000B | Short circuit on wide angle mirror actuator output | — |
| 10000C | Short circuit on front mirror actuator output | — |
| 10000D | Short circuit on close proximity mirror actuator output | — |
| 100012 | Short circuit on main and wide angle mirror heating output | — |
| 100013 | Short circuit on front and close proximity mirror heating output | — |
| 100014 | Short circuit on latch actuator output | — |
| 100015 | Short circuit on windowlifter actuator output | — |
| 100016 | Short circuit on background light output | — |
| 100017 | Short circuit on boarding step light output | — |
| 100018 | Short circuit on red warning light output | — |
| 10001B | Implausible value on Windowlifter sensor or sensor not connected | — |
| 10001C | Windowlifter position invalid | — |
| 10001D | Windowlifter overheated | — |
| 10001E | ECU defect | — |
| 10001F | ECU programming fault | — |
| 10004A | Encryption key code missing | — |
| 10004D | Overcurrent on main mirror actuator output | — |
| 10004E | Open load on main mirror actuator output | — |
| 10004F | Overcurrent on wide angle mirror actuator output | — |
| 100050 | Open load on wide angle mirror actuator output | — |
| 100051 | Overcurrent on front mirror actuator output | — |
| 100052 | Open load on front mirror actuator output | — |
| 100053 | Overcurrent on close proximity mirror actuator output | — |
| 100054 | Open load on close proximity mirror actuator output | — |
| 10005D | Open load on main/wide angle mirror heating output | — |
| 10005E | Open load on front/close proximity mirror heating output | — |
| 10005F | Overcurrent on latch actuator output | — |
| 100060 | Open load on latch actuator output | — |
| 100061 | Overtemperature on latch actuator output circuit | — |
| 100062 | Overcurrent on windowlifter actuator output | — |
| 100063 | Open load on windowlifter actuator output | — |
| 100064 | Circuit error on Windowlifter actuator output | — |
| 100065 | Open load on background light output | — |
| 100066 | Open load on boarding step light output | — |
| 100069 | Open load on red warning light output | — |
| FF8100 | Door switch module failure | — |
| FF810A | CAN timeout of corresponding DSM | — |
| FF810B | CAN timeout of DCS_D | — |
| FF810D | Door CAN bus off | — |