S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › PDS1 46 canonical DTCs
Code Heading Variants
100001 Overvoltage at main power supply —
100002 Undervoltage at main power supply —
100006 Short circuit to ground on auxiliary wake up —
100007 Short circuit to supply or implausible value on door sensor —
100008 Short circuit to supply or implausible vaule on latch sensor —
100009 Short circuit on power supply output to windowlifter sensor or windowlfiter actuator is not connected —
10000A Short circuit on main mirror actuator output —
10000B Short circuit on wide angle mirror actuator output —
10000C Short circuit on front mirror actuator output —
10000D Short circuit on close proximity mirror actuator output —
100012 Short circuit on main and wide angle mirror heating output —
100013 Short circuit on front and close proximity mirror heating output —
100014 Short circuit on latch actuator output —
100015 Short circuit on windowlifter actuator output —
100016 Short circuit on background light output —
100017 Short circuit on boarding step light output —
100018 Short circuit on red warning light output —
10001B Implausible value on Windowlifter sensor or sensor not connected —
10001C Windowlifter position invalid —
10001D Windowlifter overheated —
10001E ECU defect —
10001F ECU programming fault —
10004A Encryption key code missing —
10004D Overcurrent on main mirror actuator output —
10004E Open load on main mirror actuator output —
10004F Overcurrent on wide angle mirror actuator output —
100050 Open load on wide angle mirror actuator output —
100051 Overcurrent on front mirror actuator output —
100052 Open load on front mirror actuator output —
100053 Overcurrent on close proximity mirror actuator output —
100054 Open load on close proximity mirror actuator output —
10005D Open load on main/wide angle mirror heating output —
10005E Open load on front/close proximity mirror heating output —
10005F Overcurrent on latch actuator output —
100060 Open load on latch actuator output —
100061 Overtemperature on latch actuator output circuit —
100062 Overcurrent on windowlifter actuator output —
100063 Open load on windowlifter actuator output —
100064 Circuit error on Windowlifter actuator output —
100065 Open load on background light output —
100066 Open load on boarding step light output —
100069 Open load on red warning light output —
FF8100 Door switch module failure —
FF810A CAN timeout of corresponding DSM —
FF810B CAN timeout of DCS_D —
FF810D Door CAN bus off —
diag