S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › AXI1 AXI1 / 0DF4FF

DC link undervoltage detectedy by software

â–¶ How to fix

Check the vehicle HV DC-bus voltage for voltages below operating limits. If no voltage at the inverter terminals, check for blown aux inverter fuse in the Junction box. If fuse in fine, check for BMU faults for not closing the Battery contactor.

What you'll see

No driver-visible symptom recorded.

System reaction

System will enter error mode and switches OFF. KL15 needs to be reset, to operate the device again under normal voltage conditions.

Diagnostic depth

Detection

Input voltage voltage sensor measures a lowvoltage below 350V

Possible cause

Voltage in the Vehicle HV DC bus is below the operating limits of the device. This could be because of a blown HV fuse in the Junction box. Also, when HV battery contactors are not closed while trying to run the compressor. The battery contactors might not have closed due to other faults in the VCB system.

{ } Raw XML
diag