S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › A4 A4 / 2721

Solenoid PCS4, short circuit to battery (U30)

â–¶ How to fix

Check the cable harness between gearbox and control unit, particularly the cable to pin 55 on the control unit. If no fault is found, contact an Allison dealer.

What you'll see

No driver-visible symptom recorded.

System reaction

No system-reaction text recorded.

Diagnostic depth

Detection

The control unit has detected a short circuit to battery on the PCS4 solenoid return circuit.

Possible cause

A possible cause of this fault code is a damaged cable harness in the solenoid return circuit.

{ } Raw XML