S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › ACS6 ACS6 / 0222

Short circuit to ground or overload on proportional valve (PWM Output 5).

â–¶ How to fix

1. Check cable harness and connectors between ACS (E751) and proportional valve (V541). 2. Check proportional valve by resistance reading. Should be approx. 7-8 ohm. Replace valve if resistance is close to 0 ohm.

What you'll see

Proportional valve is deactivated, output turned off on hardware. No damping is available on the left damper, since the valve is not controllable.

System reaction

Amber ACS warning lamp Speed Limitation

Diagnostic depth

Detection

None or too low resistance in circuit connecting to proportional valve.

Possible cause

- High-side wire (B16) connecting ACS and proportional valve is short circuit to ground. - Defect connector in either ACS or proportional valve. - Defect proportional valve (internal short-circuit).

{ } Raw XML
diag