S Scania Multi 📌 unpin — ▢ ×
Pin a chassis:
Home Vehicle Parts Information Workshop Diagnostics Search Back Forward Help
V
DTC › AMS2 AMS2 / 0006A3

C3PS internal error

â–¶ How to fix

Clear the DTC memory and switch off/on the power with the starter key (U15). Run the engine for approx 1 minutes. Check if the DTC has been generated again. If the DTC has been regenerated, replace the ECU

What you'll see

Other DTC:s active, for example CAN-timeouts or ECU-reset

System reaction

No system-reaction text recorded.

Diagnostic depth

Detection

Internal powersupply ASIC is faulty or indicates internal ECU-failure

Possible cause

Internal Hardware error, overheating

{ } Raw XML
diag