Reductant pump reports supply voltage out of range.

â–¶ How to fix

Check for possible sources to the over or under voltage in the reductant pump (V183). For a detailed harness and pin description see the electrical component, under the check tab, in the diagnostic tool. For a general description about different methods for electrical failure checks see the work shop manual subgroup 16-70. In order to inactivate the electrical fault code it is necessary to restart the EEC control unit and activate the actuator. This can be done by first cycling the ignition and then running the reductant circuit test with the diagnostic tool or cycling the ignition and then running the system in such a way that the actuator is activated.

What you'll see

No driver-visible symptom recorded.

System reaction

Note: This fault shuts off the reductant flow in the system. This affects the cooling of the reductant dosing unit. Combined with high exhaust temperatures this could damage the reductant dosing unit.

Diagnostic depth

Detection

The EEC control unit (E67) is indicating an supply volytage out of range fault in the pump (V183).

Possible cause

Supply voltage to high or to low has been reported by the reductant pump.