Pump speed feedback sensor, short circuit to ground.

â–¶ How to fix

Check for short circuit to ground faults on the pins on the EEC control unit (E67) that are connected to the reductant pump (V183) speed feedback sensor. For a detailed harness and pin description see the electrical component, under the check tab, in the diagnostic tool. For a general description about different methods for electrical failure checks see the work shop manual subgroup 16-70. In order to inactivate the electrical fault code it is necessary to restart the EEC control unit and activate the actuator. This can be done by first cycling the ignition and then running the reductant circuit test with the diagnostic tool or cycling the ignition and then running the system in such a way that the actuator is activated.

What you'll see

No driver-visible symptom recorded.

System reaction

No system-reaction text recorded.

Diagnostic depth

Detection

The EEC control unit (E67) does not recieve a speed feedback signal from the reductant pump (V183).

Possible cause

1. A short circuit to ground fault on the pins connected to the pump speed feedback sensor. 2. The reductant pump is broken