DTC › AMS2 AMS2 / 001217

Reductant pump motor has turned itself of due to too high reductant pressure

â–¶ How to fix

1. Use the diagnostic tool to run the dosing test with max dosing on the downstream dosing unit, log the maximum reductant pressure measured. 2. If there is a high pressure issue somewhere in the system the pump will turn off and the test will fail 3. if the test fails, run the pump flow test 4. If fault remains, check the harness and connectors between the EEC control unit (E67) and the reductant pump (V183) for electrical failure. 5. if the pump flow test is ran without issues, if prevoiously logged pressure is below the limit replace filters, otherwise troubleshoot the return line 6. Verify that the fault is gone with the dosing test with max dosing on the downstream dosing unit 4. If no electrical failure in the harness or connectors are found, or if the filter replacement did not solve the issue change the pump.

What you'll see

The pump turns itself of for 7s or more during pressure buildup or during operation,

System reaction

No system-reaction text recorded.

Diagnostic depth

Detection

Reductant pump motorboard sends a predfined faultmode indicator over the feedback pin.

Possible cause

1. Clogged main filter in pump 2. Clogged inlet filter in dosingunit 3. Internal blockage in dosingunit 4. External force causing a flow restriction in a hose 5. Blocked return pipe in pickup unit