PM sensor power supply, short circuit to battery

â–¶ How to fix

Check for short circuit to battery faults on the pins on the EEC control unit (E67) that are connected to the particulate matter sensor (T270) supply. For a detailed harness and pin description see the electrical component, under the check tab, in the diagnostic tool. For a general description about different methods for electrical failure checks see the work shop manual subgroup 16-70. In order to inactivate the electrical fault code it is necessary to restart the EEC control unit.

What you'll see

No driver-visible symptom recorded.

System reaction

No system-reaction text recorded.

Diagnostic depth

Detection

he EEC control unit (E67) is indicating a short circuit to battery fault on the pins connected to the particulate matter sensor (T270) supply.

Possible cause

A short circuit to battery fault on the pins connected to the particulate matter sensor (T270) supply.