Event buffer full
â–¶ How to fix
Reset KL15 and Clear DTCs. If frequent, then the cause for more events or high number of DTCs from AXI has to be checked.
What you'll see
No driver-visible symptom recorded.
System reaction
System will operate with warning. No further entries can be made until the application controller has processed the error entries. The controller has failed to capture atleast one event or DTC.
Diagnostic depth
Detection
If one error event or DTC is missed by the buffer, the DTC is set.
Possible cause
The inverter's motor controller event or error memory is full. This could be because of large number of events and DTCs happening in operation