DTC › AXI1 AXI1 / 02F0FF

Event buffer full

â–¶ How to fix

Reset KL15 and Clear DTCs. If frequent, then the cause for more events or high number of DTCs from AXI has to be checked.

What you'll see

No driver-visible symptom recorded.

System reaction

System will operate with warning. No further entries can be made until the application controller has processed the error entries. The controller has failed to capture atleast one event or DTC.

Diagnostic depth

Detection

If one error event or DTC is missed by the buffer, the DTC is set.

Possible cause

The inverter's motor controller event or error memory is full. This could be because of large number of events and DTCs happening in operation

{ } Raw XML
diag